Building Constructions and Its management
For cross check of 90 dg
Hello, my name is Bhavik Mukundray Sata, and I have 22 years of work experience in construction company.
A noteworthy aspect is that even after reaching the age of 51, I undertook the Advanced Digital Marketing course at ASDM. Today, I stand as a proficient Digital Marketer, and I am the proprietor of Aadishakti Digital Marketing firm. I aspire to further enhance my business pursuits and continue progressing within the realm of entrepreneurship.
I hold a Bachelor of Arts degree in Economics and English, as well as an A grade Draftsman Civil qualification.
Additionally,
I have a strong understanding of soft skills, computer literacy, and internet surfing.
Throughout my career, I have developed expertise in areas such as sales and marketing, purchase and negotiation, site incharge, and collection and coordination. With my extensive experience and skills, I am confident in my ability to make meaningful contributions to my team or organization.
Excavation, Loads and Foundation of Building
Ø બાંધકામ માટેની જગ્યા ની પસંદગી :- (Location of Plot) :-
-
હવા, ઉજાસ અને પ્રદુષણ ને ખાસ ધ્યાન માં લેવું જોઈએ.
-
જે પ્લોટ ની
પસંદગી કરી છે ત્યાં ટેલીફોન, લાઈટ અને પાણી નું
પ્રોવીઝન હોવું જોઈએ.
-
તથા ત્યાં થી
મેઈન ડ્રેનેજ લાઈન નું કનેક્શન આસાની થી આપી શકાય તેવું હોવું જોઈએ.
-
પ્લોટ પાસે થી
નદી કે નાળા પસાર થતા હોય તો તેને ધ્યાન માં લેવું જોઈએ.
-
નજીક માં જીવન
જરૂરિયાત ની વસ્તુઓ મળતી હોવી જોઈએ.
-
આજુબાજુ માં
રહેતા લોકો નું સ્ટેટસ જાણવું જોઈએ.
-
તે એરીયા ના
ભાવતાલ વિષે ની માહિતી મેળવવી જોઈએ જેથી ભવિષ્ય માં ભાવ વધશે કે ઘટશે તેની માહિતી
આરામ થી જાની શકાય છે.
-
નજીક માં સ્કુલ, કોલેજ, હોસ્પિટલ, શોપિંગ મોલ, પાર્લરો, ડેરીઓ, કરીયાણા ની દુકાનો હોવા જોઈએ.
-
નજીક માં રેલ્વે
સ્ટેશન અને બસ સ્ટેન્ડ હોવું જરૂરી છે.
-
એટલે કે એરીયા
બધી જ રીતે ડેવેલોપ થયેલો હોવો જોઈએ.
-
પોસ્ટ ઓફીસ, પોલિસ સ્ટેશન, તથા ફાયરબ્રિગેડ
નું પ્રોવીઝન હોવું જોઈએ.
-
પ્લોટ ની જગ્યા
નીચાણ વાળી ન હોવી જોઈએ કારણકે વરસાદી પાણી તે જગ્યા એ ભરાતું ન હોવું જોઈએ. જો
ત્યાં ગટર લાઈન નું પ્રોવિઝન હોય તો તેનું પરિક્ષણ કરેલું હોવું જોઈએ.
-
પ્લોટ ના જમીન ના
સ્તરો (Strata) અને તેની માટી (Soil) ની લેબોરેટરી ચકાશણી કરેલી હોવી જોઈએ.
-
માટી ઉપર પાથરતા
લોડ ની પણ ચકાશણી કરવામાં આવે છે જે તેની આસપાસ ના બાંધકામ ઉપર થી ખ્યાલ આવી જતો
હોય છે. માટી ક્ષાર મુક્ત હોવી જોઈએ અને ઉધઈ ન
હોવી જોઈએ.
-
માટી સારી હોવી
જોઈએ જેથી લેન્ડસ્કેપિંગ કામ થઇ શકે અને ગાર્ડન પણ વિકસિત થઇ શકે.
-
પ્લોટ ની નજીક
કોઈપણ પ્રકાર ની ફેક્ટરી, ઉદ્યોગ, નાના કારખાના કે તેમાંથી નીકળતો ધુંવાડો ન હોવો જોઈએ કે
કોઈપણ પ્રકાર નો વધુ પડતો ઘોંઘાટ ન હોવો જોઈએ.
-
પ્લોટ બને ત્યાં
સુધી મેઈન રોડ ની નજીક નો હોવો જોઈએ.
-
બહુજ ધૂળ કે માટી
વાળો વિસ્તાર ન હોવો જોઈએ.
-
ખાસ અગત્યનું કે
જમીન કે પ્લોટ ઉપર કોઈપણ પ્રકાર નો બોજો (લેવડ દેવડ) ન હોવો જોઈએ.
-
પ્લોટ કે જમીન
નું ટાઇટલ ક્લીયર હોવું જોઈએ.
Ø પ્લોટ નો સર્વે અને તેનું લેવલીંગ (Survey and Levelling of Plot) :-
-
જેમાં સૌ પ્રથમ સર્વે
કરવામાં આવે છે જે જમીન ના ઊંચાણ કે નીચાણ ના ભાગો ને દર્શાવે છે. સર્વે જમીન નું
લેવલીંગ કરવા માટે ખુબ જરૂરી છે. ત્યાર બાદ જમીન નું લેવલીંગ કરવા માં આવે છે, જે JCB અથવા તો Bull Dozer દ્વારા કરવામાં
આવે છે. લેવલીંગ મુખ્યત્વે બે રીતે કરવામાં આવે છે.
-
(૧) Theodolite Instrument થી અને (૨) Dumpy Level થી કરવામાં આવે
છે.
-
બીજા ઘણા જ
પ્રકારે સર્વે થતા હોય છે જેમકે : Contour Survey અને Chain Survey
-
આ સર્વે એજન્સી
દ્વારા કરવામાં આવે છે જો બાંધકામ નાનું
હોય તો એન્જીનીયર જાતે જ કરે છે.
Ø જમીન ના સ્તરો અને તેની માટી ની ચકાસણી (Test of Soil and Strata) :-
-
ઢીલી અને કઠણ
માટી (Soft and Hard Soil)
-
કાળી માટી (Black Cotton Soil)
-
લાલ માટી (Red Soil)
-
ચીકણી માટી (Shadu Soil)
-
કઠણ પથ્થર (Hard Rock)
-
કઠણ મૂરમ માટી (Hard Murum Clay)
-
ઢીલી મૂરમ માટી (Soft Murum Clay)
-
સામાન્ય પથ્થર (Ordinary Rock)
-
સામાન્ય માટી (Ordinary Clay)
-
આવી અન્ય માટી ઓ
માં – Alluvial Soil, Moist Clay, Made up Soil, Compact Clay, Loose Sand, Fine Sand, Kankar, Sandy Gravels, Loose Gravels, Gravels. આમ ચકાસણી
બાદ એન્જીનીયરીંગ ડ્રોઈંગ પ્રમાણે ખોદકામ (Excavation Work) શરુ કરવામાં આવે છે.
Ø
ખોદકામ (Excavation
Work) :-
-
પાયા ના ખોદકામ
ડ્રોઈંગ મુજબ કરવામાં આવે છે. જેમાં સૌ પ્રથમ બિલ્ડીંગ નું લે આઉટ જમીન ઉપર
છાપવા માં આવે છે.
-
જે લાઈન નો આધાર
નજીક ના રોડ ઉપર થી નક્કી કરાય છે.
-
લાઈન દોરી ને
છાપવા સૌ પ્રથમ બધી જ સેન્ટર લાઈન (દીવાલો સાથે) ની છાપવા માં આવે છે. ત્યારબાદ
ખોદાણ કામ માટે ના પ્લાન મુજબ સેન્ટર લાઈન
ની બંને બાજુ એ ખોદાણ માટે ની લાઈન છાપવા માં આવે છે.
-
છાપવા ની વિધિ
પૂરી થઇ ગયા બાદ તેને ફરી ચેક કરવા માં આવે છે જો કોઈ ભૂલ થઇ હોઈ તો આ જ સમયે
સુધારી શકાય છે નહીતર સ્ટ્રકચર નકામું બની જાય છે. અને એ ભૂલ આગળ જતા બહુ જ મોટું
નુકશાન કરાવે છે. માટે એન્જીનીયર દ્વારા ચેક કરાવવું જરૂરી છે.
-
ડ્રોઇંગ પ્રમાણે
ખોદકામ શરુ કરવા માં આવે છે. ખોદકામ કરતી વખતે જો કોઈ ઝાડ, ડ્રેનેજ લાઈન, પાણી ની લાઈન, ઇલેક્ટ્રિક કે
ટેલીફોન ના વાયરો જો ખોદકામ માં અડચણ રૂપ હોય તો કે જમીન નું સ્તર ખુબ સખત હોય (Hard Strata) તો આ માટે ઓથોરીટી ની પરવાનગી જરૂરી છે, જે અમદાવાદ કોર્પોરેશન માંથી લેવાની રહે છે. ખોદકામ કરતી વખતે ધ્યાન માં
લેવાતા મુદ્દાઓ -
-
ખોદકામ કરતી વખતે
ખાડો “V” સેપ માં બનવા માં આવે
છે જેથી માટી નું ઉભું લેયર ખાડા માં રહેલા મજુરો ઉપર પડે નહિ, બીજું કે માટી ને બહાર જયારે ફેંકવા માં આવે ત્યારે તેને
ઓછામાં ઓછું બે ફૂટ દુર ફેંકાય છે, જેથી એ ફરી ખાડા માં ન
પડે.
-
સાઈટ
ઇન્ચાર્જ દ્વારા લેવાતી કાળજી ઓ – જયારે ખોદકામ
ચાલી રહ્યું હોય ત્યારે બધા નું હિત ધ્યાન માં રાખી થોડી કાળજી લેવી પડતી હોય છે, મેદાન માં કોઈ પણ પ્રકાર ની ખીલી કે તીક્ષ્ણ વસ્તુઓ ન હોવી
જોઈએ જે કોઈ ને પણ ઈજા કરી શકે છે. જો ખીલી પ્લેંક માં લાગેલી હોય તો તેને તેમાંથી
કાઢી ને કચરા માં સાચવી ને રાખવી જોઈએ. કોઈપણ પ્રકાર ના મજુરો ને સેફટી નું
માર્ગદર્શન આપેલું હોવું જોઈએ અને તે, તે પ્રકારે અનુસરી રહયો છે કે કેમ તેનું
ધ્યાન પણ રાખવા માં આવતું હોય છે. સેફટી ગમબુટ, હાથ ના મોજા તથા માથા ઉપર હેલ્મેટ
પહેરેલી હોવી જોઈએ. Safety Precaution માટે અલગ થી મૂદ્દો આગળ આવશે. ખોદકામ ચાલી રહયું હોય
ત્યાંથી loaded Truk ને પાસ ન થવા દેવો જોઈએ, કારણકે તેના
દબાણ થી માટી ખાડા માં ધસી જશે અને મોટી દુર્ઘટના ઘટી શકે છે. તેમજ મજુરો ના રમતા
બાળકો નું ખાસ ધ્યાન રાખવું પડતું હોય છે. જયારે Truk Reverse લેતા હોય છે. Truk રહેલા કલીનરે Truk માંથી બહાર આવી ને Driver નું માર્ગદર્શન
કરવું જોઈએ, જેથી કોઈ પણ પ્રકાર ની
દુર્ઘટના ના ઘટે. ઈલેક્ટ્રીક ના વાયરો ના છેડા બરાબર જોડેલા હોવા જોઈએ તેમજ તેનું Earthing કરેલું હોવું જોઈએ, અને એ વાયરો ને યોગ્ય રીતે પાથરેલા કે
લટકાવેલા હોવા જોઈએ. ખાડા માંથી બહાર નીકળવા માટે સીડી નો જ ઉપયોગ કરવો જોઈએ.
-
Basement, Mass and Deep Excavation Work – જો પાર્કિંગ માટે કે કોઈ જમીન નું મોટા પ્રમાણ માં ખોદકામ
કરવા માં આવે તો અમુક બાબતો નું ધ્યાન રાખવું પડે છે. જેમકે ખાડા માં ઉતરવા માટે Ramps (યોગ્ય ઢાળ) બનાવો જોઈએ જેથી Trucks ની અવર જવર સારી રીતે અને અટકયા વિના થાય જોકે ચોમાસા દરમ્યાન
આવું કોઈ પણ કામ કરવા માં આવતું નથી. જો જમીન માંથી પાણી નીકળે થોડું તો તેનો
તાત્કાલિક ઉપાય કરવો જોઈએ.
-
પાણી
માં થતું કોઈપણ પ્રકાર નું ખોદકામ – ઘણી વખત પાણી ની નીચે ખોદકામ કરવા પડતા હોય છે, જે માટે જો વહેતું ઝરણું હોય તો તે માટે તેની Trench બનાવી ને બીજી દિશા તરફ વાળી ને કામ કરી શકાય છે. પરતું જો
સ્થીર પાણી હોય જેમકે નદી કે તળાવ કે જેની ઉપર પુલ (Bridge) બનાવાનો હોય, ત્યાં Cofferdams નો ઉપયોગ કરવો પડતો હોય છે. આ Dams ની વિગતવાર ચર્ચા આગળ કરીશું.
-
ખોદકામ જયારે
પૂર્ણ થઇ જાય ત્યારે ખાડા ને વ્યવસ્થિત સાફ કરવા માં આવે છે. ત્યાર બાદ ઉધઈ ન આવે તે માટે ની ટ્રીટમેન્ટ કરવામાં આવે
છે. જે ખાડા ના નીચે ના ભાગ માં રહેલી માટી સાથે કરવા માં આવે છે. ખાસ નોંધ : પાયા
માં Footing work પહેલા જ કરવા માં આવે છે.
-
ખોદકામ કાર્ય બાદ
માટી ધસી ન આવે તે માટે ખાડા માં Shuttering કરવા માં આવે છે.
જેથી પાયા નું કામ કરતી વખતે માટી ધસી ન પડે ખાડા માં એ બાબત નું ચોક્કસ ધ્યાન
રાખવા માં આવે છે. આ shuttering કામ કરતી વખતે
એન્જીનીયર નું માર્ગદર્શન જરૂરી રહે છે.
Ø માટી ની સુરક્ષિત અસર ક્ષમતા (Safe Bearing Capacity)
-
The Capacity of the soil that supports the structure load
to the ground without any shear failure
or settlement is called Safe Bearing Capacity of the Soil.
-
The Safe Bearing Capacity of Soil = Ultimate Bearing
Capacity (UB) / Area x Factor of Safety and Ultimate Bearing Capacity of Soil =
Width X Height X Depth.
-
As we all know that, The Strength of Building, Roads,
Dams etc. All are dependent on the Foundations and Foundation is dependent on
the Soils. If has high Bearing Capacity then It will bear high loads and
Pressures which are an important part of the construction of the buildings,
Roads and Dams.
-
The various methods of computing the Bearing Capacity can
be listed here –
Presumptive Analysis
Analytical Methods
Plate Bearing Test
Penetration Test
Modern Testing Methods and
Centrifuge Test.
-
Seven Method to Improve the bearing Capacity of Soil –
The following techniques can be used for improving
Bearing Capacity of Soil as per the Site condition –
Increasing depth of foundation
Increasing the depth of the foundation is the simplest
method for improving the bearing capacity of soil. This method is especially
used for sandy soils. Because mostly sand have too low bearing capacity as
compared to other type of soil.
Draining the Soil
Drainage is another well-known method which improves the
bearing capacity of soil. The Bearing Capacity of every soils decrease with
increase in water content. In case of sandy soil the bearing capacity may
reduce as much as 50% due to presence of water content. Note – This
method is most effective for sandy and gravels soils But, Not for Clay type of
soils.
Compacting the Soil or Driving Sand Piles
If we compact soil using appropriate method, then There
will be increase in its density and Shear Strength. There are many method of
compacting soils on site. In this method certain amount of granular material
such as sand, gravels, crusted stones etc.
is blended into the weak soil
Confining the Soil
This method is applicable for Shallow Foundations.
For this purpose mostly sheet Piles are used. They are driven to from an
enclosure, which compacts the soil particles. Thus it will help in increasing
the bearing power. This method is suitable for sandy soils.
By Grouting
This Method is applicable for soils where there is
presence of pores, fissures or cracks etc. Underneath the foundation. This
method is mostly employed for fissured cracks.
Stabilizing the soil with chemical
This method of improving bearing capacity of soil is
costly and adopted in exceptional cases. In this method, Chemical solutions,
like silicates of soda and calcium chloride is injected with pressure into the
soil.
Replacing the poor soil
In this method the poor soil is first removed and then
the gap is filled up by superior materials such as sand, Stone gravels and
other hard material. This method is useful for foundation in Black Cotton
Soils.
|
No.
|
Strata or Soils
|
Safe Bearing Capacity
In Tonnes / sq. m.
|
|
1
|
Very Soft, wet and
Pasty Clay
|
0 to 5
|
|
2
|
Black Cotton Soil
(Dry)
|
4 to 10
|
|
3
|
Red Soil
|
10 to 30
|
|
4
|
Shadu Soil
|
20 to 30
|
|
5
|
Loose Gravels
|
15 to 25
|
|
6
|
Murum
|
25 to 45
|
|
7
|
Soft Rock
|
25 to 45
|
|
8
|
Hard Rock
|
Ø 90
|
|
9
|
Alluvial Soil
|
5 to 8
|
|
10
|
Alluvial Loam
|
8 to 16
|
|
11
|
Moist Clay
|
11 to 18
|
|
12
|
Made up Soil
|
5
|
|
13
|
Ordinary Clay
|
22
|
|
14
|
Clay mix with sand
|
22
|
|
15
|
Compact Clay
|
33 to 35
|
|
16
|
Loose Sand
|
22
|
|
17
|
Compact Sand
|
22 to 32
|
|
18
|
Compact and Fine
Aggregates
|
44
|
|
19
|
Kankar & Sandy
Gravels
|
22 to 32
|
|
20
|
Compact Gravels
|
44 to 60
|
|
21
|
Ordinary Rocks
|
Ø 250
|
-
Mathematically –
Safe Bearing Capacity = Bearing Capacity / Factor of
Safety.
-
Laboratory Tests :-
Protector Compression Test
Moisture Content Determination
Consolidation Test
Liquid Limit Test
Shear Test
Shear Box Test
Tri-Axial Compression Test
Unconfined Compression Test
Penetration Test
-
Field Test :-
1] A pit is excavate up to the Strata which is to be
tested
2] The bottom of the pit is levelled
3] Load is applied on the bearing plate, which is four
times the designed load
4] Settlement is recorded after every 24 hours
5] Recording is done till there is no settlement in 24
hours
6] Settlement under test load should not be more than 20
mm
7] Loading can be done using cement bags or sand bags.
Ø પાયા ઉપર આવતા ભાર કે વજન (Types of Loads on Foundation)
પાયા ઉપર આવતા વજનો ની
વિગત નીચે મુજબ ક્રમાનુસાર છે.
-
સ્થીર વજનો (Dead Loads) –
જે સ્થીર હોય છે, જેમાં કોઈપણ પ્રકાર ની મુવમેન્ટ જોવા મળતી નથી જેવાકે – Super Structure, Columns, Beams, ઇંટો – પ્લાસ્ટર
– તે માંથી બનેલી દિવાલો, સ્થીર Furnitures, છતો, લીન્ટેલ, છજાઓ, lofts, Steel Structures, ધાબા ઉપર ની
પાણી ની ટાંકી, દરવાજા અને બારીઓ, ફ્લોરિંગ ની ટાઈલ્સ નું વજન, Sub-Structure નું વજન વગેરે.
-
હરતા ફરતા વજનો (Live Loads) –
એવા વજનો કે જે અસ્થાયી
હોય છે. જેવા કે- મકાનો માં ફરતા માણસો ના વજન, મુવેબલ Furniture, હંગામી ધોરણ વાળું વજન, છત ના પંખો, AC નું Vibration વગેરે. બિલ્ડીંગ તરીકે તેના ઉદાહરણો Hospitals, Educational Building, Schools, Colleges, Institutes,
Cinema Halls, Town Halls, Residential Buildings, Offices or Commercial
Buildings, Banks, Public Halls, Ware House, Dancing Halls, Hotels, Motels,
Upper Level Swimming Pools in Highrise Buildings, Malls, Factories વગેરે.
-
હવા નું દબાણ
ઉભું થવા થી વજન (Wind Loads) –
આપણે જાણીએ છીએ કે જેમ
બિલ્ડીંગ ની ઉંચાઈ વધે તેમ તેના ઉપર હવા નું એક સતત દબાણ રહેતું હોય છે. સામાન્ય
રીતે આ દબાણ વધુ પડતા ઊંચા બિલ્ડીંગો માં જોવા મળતું હોય છે. જે વજન ને ધ્યાન માં
રાખી જયારે બિલ્ડીંગ ઉપર ના વજન ની ગણતરી થતી હોય ત્યારે આ બાબત ની નોંધ પણ લેવી
જરૂરી છે. હવા ના દબાણ થી બચવા માટે ઘણી બિલ્ડીગો માં અમુક ફલોર ને ખુલ્લા (Open) રાખવા માં આવે છે જે હવા ની અવર જવર માટે જ હોય છે. જે
સ્ટ્રકચર ડીઝાઈનર નક્કી કરે છે.
-
બરફ નો ભાર કે
વજન (Snow Loads) –
બરફ નું વજન સામાન્ય રીતે
વિદેશો માં અથવા પહાડો કે હિમાલય પ્રદેશ માં જોવા મળે છે અથવા જ્યાં બરફ નો મોટો
ભાગ હિમ વર્ષા તરીકે જોવા મળે છે. જયારે
બરફ ની ચાદર આખા બિલ્ડીંગ ને ઢાંકી દે છે ત્યારે તેનું પણ વજન પાયા ઉપર પડે છે.
જેનાથી બચવા માટે વજન નક્કી કરતી વખતે આ બાબત ને ધ્યાન માં રાખવી જોઈએ.
-
ભૂકંપ ના ઝાટકા
સહન કરવા (Earthquake Shocks) –
આપણે જાણીએ છીએ ખુબજ સારી
રીતે કે ભૂકંપ ના ઝટકા ખુબ અસર કરે છે બિલ્ડીંગો ને જે ગુજરાત માં આવે લ ભૂકંપ થી
ગુજરાત રહેતા ગુજરાતીઓ આનાથી વાકેફ જ હશે. ૨૬ જાન્યુઆરી ૨૦૦૦, લગભગ ભૂકંપે આખા
વિશ્વ ની યાત્રા કરેલી એ સમયે. માટે જયારે બાંધકામ માં વજન ની ગણતરી કરવા માં આવે
ત્યારે આ પ્રકાર ની સહન કરી શકાય તેવી રચના Structural Designer એ કરવા ની રહે
છે. ભૂકંપ થી મકાનો ને ખુબ નુકશાન થાય છે, ઘણી વખત
બિલ્ડીંગો પડી જાય છે. ત્યારે પાયા ની Design Load Bearing Foundation પ્રમાણે ની હોવી જોઈએ.
-
ધુળ કે માટી નું
વજન (Dust Loads) –
ધૂળ કે માટી જયારે વંટોળ
બની ને હવા માં પ્રસરે છે ત્યારે થોડા ભાગ ની ધૂળ કે માટે મકાન માં આવેલી ખનીજ
ખાંચા ખૂંચી વાળી જગ્યા એ રહી જાય છે. આમ જોવા જઈએ તો આનું કઈ ખાસ વજન હોતું નથી
પણ સમય વિતતા એ વજન નજીવી દ્રષ્ટિ એ બિલ્ડીંગો ઉપર પડતું હોય છે. જેને નજરઅંદાઝ ન
કરવું જોઈએ.
-
ગુરુત્વાકર્ષણ બળ
(Gravity Force) –
ગુરુત્વાકર્ષણ બળ અને
જમીન માંથી થતું પાયા ઉપર નું પ્રેસર ઘણા અંશે બિલ્ડીંગો ને અસર કરતુ હોય છે. આવા
ઘણા પરિબળો ને ધ્યાન માં રાખી જયારે મકાન બાંધકામ માટે Loads ની ગણતરી કરીએ ત્યારે તે ગણવા માં આવે છે.
-
મકાન નું માળખું
અને જમીન માં રહેલો તેનો પાયો (Sub-Structure and Super Structure) –
મકાન બાંધકામ ની શરૂઆત માં પાયો તેનું મુખ્ય સ્વરૂપ કે આધાર
છે જેને આપણે Sub-Structure કહીએ છીએ કે જે જમીન ની અંદર નું બાંધકામ અને પ્લીન્થ લેવલ
(Plinth Beam) સુધી નું હોય
છે. જે મકાન નો મુખ્ય આધાર છે. પાયા ના ઘણાં જ પ્રકારો છે જે આગળ આપણે જોઈશું.
તેવી જ રીતે જમીન થી ઉપર ભાગ ને એટલે કે પ્લીન્થ બીમ થી છેક ધાબા સુધીના ભાગ ને Super Structure કહેવાય છે. આ
બનેલા માળખા ઓ નું વજન પાયા દ્વારા જમીન માં રહેલી માટી (Soils) અને માટી દ્વારા બનેલા સ્તરો (Strata) ઉપર પથરાય છે. જયારે Loads બિલ્ડીંગ માટે
નક્કી કરતા હોઈએ ત્યારે બધી જ બાબતો નું ધ્યાન રાખવા માં આવતું હોય છે. જે માટે Structure Designer ની હાજરી જરૂરી
હોય છે.
Ø પાયો તથા પાયા ની ભરાઈ નું કામ (Foundation and Footing Work)
-
મુખ્યત્વે પાયા
ના પ્રકાર બે છે. જેમાં Shallow Foundation કે જે Depth < Width એટલે કે ખાડા ની
પહોળાઈ જે હોય છે તેનાથી ખાડા ની ઊંડાઈ ઓછી અથવા બરાબર હોય છે. Footing
is one of the most important part of a structure which transfers load of
structure to the under laying soil of earth and the selection of footing depend
upon the following factors. (1) The Depth of the Soil at which Safe Bearing
Capacity strength exists, (2) Type and Condition of Soil and (3) Type of Super
Structure
અને Deep Foundation આ પાયા માં Depth > Width એટલે કે જયારે
ખાડા પહોળાઈ કરતા ખાડા ની ઊંડાઈ વધુ હોય છે. The
depth of foundation is much greater than It’s width
-
(૧) Shallow Foundation - Single / Spread Footing
It is common to use, The base of structure enlarges or
spread to provide individual support. There are many types of foundation which
spread foundation – Wall Footing, Isolated Footing, Strap Footing, Combine
Footing, Inverted Arch Footing, Grillage Footing and Raft / Mats Footings are
called Spread Footing.
Combined Footing
This footing is used for 2 or more than 2 columns
constructed they are close with each-others and their foundation overlap and
this foundation is to transmit the load from the structure to the underlying
soil.
Rafts and Mats Footing
These foundations are spread across the entire area of
the building to support heavy structure load from columns and walls.
Inverted Arch Foundation
This type of
foundation used in such places where the bearing capacity of the soil is very
poor and load of the structure is concentrated over the pillars. The other
conditions of soil are such that deep excavation are also not possible.
Stepped Footing
This type of foundation provided on hilly spaces or in
those situations where the ground is sloppy in this foundations the excavation
trenches are made in the form of steps. All steps should be preferable of equal
length and depth.
Strapped Footing / Cantilever Footing
It’s type of combine footing, Consisting of two or more
column footings connected by a concrete beam. This type of beam is called a
strap beam. It is used to help distribute the load of either heavily or
Eccentrically loaded column footings to adjacent footing and This Foundation
called Cantilever, Strapped and Balance footing too.
Strip Footing / Wall Footing
The width of the wall, foundation is usually
2 – 3 times the width of wall. The wall footing is a continuous slab strip
along the length of the wall. Stone, Brick and Reinforcement Concrete etc. are
used for the construction of wall.
Individual Footing / Isolated Footing
It is Common type of footing, This foundation is
constructed for single column and also called a Pad Foundation. The shape of
Individual footing is square or rectangle and this is used when loads from the
structure is carried by the columns
Sloped Footing
Where the nature surface of ground is slopped, the most
economical solution may be a stepped foundation, in this case, the foundation
takes the form of a series of concrete horizontal steps following the slope of
the ground.
Inverted Arch Footing
Inverted Arch Footing used in places where the bearing
capacity of the soil is very poor and the load of the structure is concentrated
over the walls and dep excavations are not possible. This is not a common
type of foundation Arched constructed between the two walls of the base.
Grillage Footing
Type of Isolated
Foundation, Generally provide for heavily loaded steel stanchions, It’s use in
the location where safe bearing capacity of soil is very poor.
-
(૨) Deep Foundation - Pile Foundations –
A Pile foundation is a long cylinder of a strong material
such as concrete that is pushed into the ground to act as a steady support for
structure built on top of it. It is used in these situations – When there is a
layer of weak soil at the surface. This layer cannot support the weight (Load)
of the building, so the loads of the building have to bypass this layer and be
transferred to the layer of stronger soil or rock that is below the weak layer
and its done by Piles. Second thing is when a building has very heavy,
concentrated loads, such as in a high rise structure, Bridges or water tanks. There
are two fundamental types of pile foundation – Based on Structural behaviour
and Each of which works in its own way.
o End Bearing Pile
Foundation
In the End Bearing Pile Foundation the bottom end of the
pile rests on a layer of especially
strong soil or rock. The load of the building is transferred through the pile
onto the strong layer.
o Friction Pile
Foundation
This type of pile utilizes the frictional resistance
force between the pile surface and adjacent soil to transfer the Super
Structure load. Depending on the Sub-Soil Strata condition, resistance force
due to friction can develop in a definite pile length of on the full length.
o Anchor Pile
Foundation
This pile is also known Tension Piles and Uplift Piles,
That is used to resist uplift forces that might otherwise cause it to be
extracted from the ground. Uplift forces can develop as a result of hydrostatic
pressure, Seismic activity or overturning.
o Batter Pile
Foundation
The Pile that is driven through a soft soil until it
reaches to a strong base.
o Compaction / Sand
Pile Foundation
Compaction piles are used to compact loose granular soil,
thus increasing their bearing capacity. The compaction piles themselves don’t
carry load. The pile tube, driven to
compact the soil, is filled in its place thus forming a sand pile.
o Frankie Pile
Foundation
Frankie Pile is Suitable for granular type of soils and
for soil bearing capacity stratum of limited thickness is located at reasonable
depth. This type of pile has mushroom shape bottom which acts like spread
footing.
o Drilling / Auger
Pile Foundation
Auger cast piles are a type of drilled foundation in
which the pile is drilled to the final depth in one continuous flight auger.
During drilling the flights of the auger are filled with soil, Providing
lateral support and maintaining the stability of the hole.
o Under Reamed
Pile Foundation
These piles are bored cast in situ concrete piles having
one or more number of bulbs formed by enlarging the pile stem. These piles are
best situated in soils where considerable ground movements occur due to
seasonal variations, filled up grounds or in soft soil strata.
o Mc-Arthur
Pedestral Pile Foundation
This is compressed concrete pile. This type of pile cased
Pedestral concrete pile. The rammed in place the pile is advantageous where it
is desired to spread load on a relative thin bearing stratum.
o Screw Pile
Foundation
Sometimes referred to as screw anchors, Screw Pile,
Helical Piles and Helical anchors Piles are Steel screw in piling and ground
anchoring system used for building deep foundations. Screw piles are
manufactured using varying sizes of tubular hollow sections for the pile or
anchors shaft.
o Composite Pile
Foundation
This pile is commonly used consists of a steel pile or
H-pipe at the bottom and cast in situ concrete pile at the top. This type of
pile is recommended in cases where the designed length of the pile works out to
be greater than that available for the cast in situ type pile.
o Simplex Pile
Foundation
This pile is useful for both soft and Hard Soils. To
obtain simplex pile. A steel tube with cast Iron shoe is driven into the ground
up to desired depth. After that, reinforcement is provided in the tube and
then, the tube is slowly removed and cast iron shoe is left at the bottom.
o Fender Pile
Foundation
Fender piles are made up of timber. When piles driven in
granular soil with the aim of increasing the bearing capacity of the soil, the
piles are termed as compaction piles.
o Timber, Steel
and Reinforced Concrete Pile
Normally Pile foundations are deep foundations. They are
formed by long, Slender, Columnar elements typically made from Steel,
Reinforced Concrete and Timber. This type of foundations described as Piled
when its depth is more than three times of width.
o Concrete Pile
Foundation
When Driven piles made of Concrete, They are precast.
These piles are driven using a pile hammer. When these piles are driven into
the granular soils, they displace the equal volume of soil. This helps in
compaction of soil around the sides of piles and results in the densification
of soil.
o Raymond Concrete
Pile Foundation
Raymond Steep Taper Concrete Piles. This type of core
driven pile is used either as an end bearing pile can be driven in any type of
soil.
o Steel Pile
Foundation
Commonly used Steel Piles are rolled steel “H” Section
piles or Pipe Piles. The piles have either an open or a closed end that is
driven into the ground “I” Section or wide flange piles can also used as pile.
o Precast Pile
Foundation
When Driven piles are made of concrete, They are precast.
These piles are driven using a pile hammer. When these piles driven into the
granular soils, they displace the equal volume of soil, This helps in
compaction of soil around the sides of piles and results in the densification
of soil.
Cofferdams Foundations –
Cofferdams are
structure that retaining water and soil that allow and the end closed area to
be pumped out and excavate dry. It’s used for Construction of Bridges piers and
other support structure built within water.
o Earthen
Cofferdam Foundation
Constructed at the place where the height of the water is
less say 3 m and the current velocity is low. These dams are built using the
local available materials such as clay, fine sand and evensoil, The height of
dam is kept 1 m more than that of max water level.
o Rock-Fill
Cofferdam Foundation
This is better than Earthen Dam, These Dams are preferred
when the rock is available easily at the construction site. These Dams are very
pervious, to prevent water from seeping an impervious membrane of soil is
provided in the dam.
o Single / Double
Walled Cofferdams Foundation
Single walled become unfeasible as larger areas are
required in deeper water and so. And Double Walled are sometimes necessary.
Double walls are built with a gap between them, the thickness of which is
dependent upon the depth of water.
o Crib Cofferdam
Foundation
In deep waters where it is difficult to penetrate the
guide piles or Sheet piles into the hard bed below crib. In this type of
construction, the sheet piles are supported by a series of wooden crib.
o Sheet Piles for Cofferdam
Foundation
This type of pile is suitable when it is required to
exclude water over 36 feet. This consists of two straight, parallel vertical
wall of Sheet piling tied to each other and the space between them filled with
soil. Sheet pile higher than 7.5 feet should be strutted.
o Cellular
Cofferdam Foundation
The Cells are interconnected to form a watertight wall. These
are filled with soils and as a result, provide stability against the lateral
forces. Also known as a Diaphragm.
Caisson Foundations –
Caisson
Foundation also called as piers Foundation, It is a watertight retaining
structure used as a bridge pier, in the construction of a concentrate dam or
for repair ships. They are created by auguring a deep hole into the ground and
then filling with concrete. The different between Caisson and Piles are Pile
foundation is deep foundation, in which loads are taken to a low level by
means of vertical timber, Steel and Concrete. Caisson Foundation is
putting a box into under the water and pouring it with concrete pile is a
column of material driven by a pile driver.
o Open Caisson
Foundation
These are small cofferdams that are placed and then
pumped dry and filled with concrete. These are generally used in the formation
of a pier.
o Box Caisson
Foundation
Boxes and Cylinders that are mainly used for under water.
It is a prefabricated hollow box or cylinder sunk into the ground to desired
depth and then filled with concrete thus forming a foundation. Caisson
Foundation is most often used in the construction of bridge piers and other
structures that require foundation beneath rivers and other bodies of water.
o Pneumatic
Caisson Foundation
Pneumatic are larger watertight. The compressed air is
used to remove water from the working chamber and foundation work is carried
out in dry condition. This type of caisson made by timber, Steel and Concrete.
Pier / Post Foundations –
Normally two
method for Piers Foundations –
Masonry /
Concrete Pier – Masonry or concrete piers depend on the level of the
stratum. If a good bearing stratum exists up to 5 m, Masonry piers are used.
The sizes and Shapes of Piers depend on the nature of soil, Depth of the bed
etc.
Spacing of Pier
foundations - usually are built 1’.6” feet above the ground. This gap
is necessary to prevent the moisture as the moisture damages the wooden
structure.
Shape and Sizes
of Piers – There are Square, Rectangular, Circle. The Diameter of Piers is usually
6”, 8”, 10” and 16”. The depth of Piers foundation is below the freezing depth.
The depth is around 5 to 6 ft.
The Piers can be
made from varied materials like – Wooden, Bricks and Solid Concrete.
Advantage of
Piers are – This method is very easy and less amount of materials and labours.
Material required here is easily available in the market. Save money and time
as it does not need extensive excavation and lot of concrete. Inspection is
possible as the design whenever they want if necessary. The ground vibration
that is normally associated with driven piles is a absent in case of drilled
piers construction. Bearing Capacity can be increased by under-reaming the
bottom.
Drilled Caissons
Pier– usually refer to the cylindrical foundation. A Drilled Caisson is largely
a compressed member subjected to an axial load the top and reaction at the
bottom. There are three types of drilled caissons – Concrete
caisson with enlarged bottom, Caisson of steel pipe with concrete filled in the
pipe and Caisson with concrete and steel core in the steel pipe.
A Pier
foundation is a collection of large diameter cylinder columns to support the
Super Structure and Transfer large Super – Imposed loads to the firm Strata
below. It stood several feet above the ground. It is as known Post
Foundation too. Pier is a vertical Cylinder column of relatively larger
cross section than a pile foundation.
Hello, my name is Bhavik Mukundray Sata, and I have 22 years of work experience in construction company.
A noteworthy aspect is that even after reaching the age of 51, I undertook the Advanced Digital Marketing course at ASDM. Today, I stand as a proficient Digital Marketer, and I am the proprietor of Aadishakti Digital Marketing firm. I aspire to further enhance my business pursuits and continue progressing within the realm of entrepreneurship.
I hold a Bachelor of Arts degree in Economics and English, as well as an A grade Draftsman Civil qualification.
Additionally,
I have a strong understanding of soft skills, computer literacy, and internet surfing.
Throughout my career, I have developed expertise in areas such as sales and marketing, purchase and negotiation, site incharge, and collection and coordination. With my extensive experience and skills, I am confident in my ability to make meaningful contributions to my team or organization.
Subscribe to:
Comments (Atom)